Revision function high precision dispenser belonging to
SuperΣ®xIII
"Dispense stability" of excellence
・High precision dispense of the highest quality kept on polishing
・Operability improves
・High cycle time high throughput
・We contribute to running cost down
・It is all-in-one in Full Automation revision function
Specifications
Name
High precision dispenser with revision function
Model
S-SIGMA-X3-V5
S-SIGMA-X3-V2
Dispensing method
Air pulse
Discharge pressure setting
Microcomputer control electro/pneumatic method
Dispense mode
Timed mode/manual mode
Discharge pressure setting range
0.010-0.500 MPa
0.005-0.200 MPa
Discharge time setting range
0.001 ... 9999.999s
Vacuum pressure set range
-0.020-0 MPa
-0.010-0 MPa
Main function
Water head difference automatic compensation, dripping automatic prevention, automatic residual quantity warning, α revision, δ revision,
Vacuum pressure revision, residual quantity indication revision, dispense counter, stopwatch,
Japanese-English indication reshuffling, exhaust error, pressure change error, pressure over error,
Vacuum pressure error, solenoid valve error, solenoid valve warning
The number of the channels
100 CH
RS-232C serial communication
Possibility
Input signal
We pre-set dispense, channel reshuffling, dispense mode reshuffling, channel,
Channel designation, channel step
Output signal
While is completed, and dispense cycles among dispense lady, dispense, pressure change error,
Under solenoid valve alarm, error, residual quantity warning, electricity
Rating power supply and frequency
AC100-240 V 50/60 Hz
Power Consumption
30W
Conformity standard
CE marking (low voltage order, EMC order)
EU RoHS
Exterior dimensions W*D*H
W300 X D250 X H100 mm
Weight
5.4 kg
Note: When you use syringe, cartridge more than 70 ml, please consult to us.
External representation